Project

# Title Team Members TA Documents Sponsor
32 Ferrofluid Lava Lamp
Hanyao Zhang
Ting-Wei Hsu
Zhiyuan Yao
Luke Wendt design_document0.pdf
final_paper0.pdf
other0.pdf
presentation0.pptx
proposal0.pdf
video
video
Our project consists of creating a decoration similar in concept to a typical lava lamp, but using ferrofluid and magnetism instead of wax and heat. We would also like to allow the user a good degree of interactivity with the display.

The design is as follows:
A ferrofluid will first be mixed into a liquid of similar density. This will then be placed into a glass cylinder, at the top and bottom of which will be electromagnets. This will be used to control the upwards and downwards flow of the ferrofluid.
Our design will also have electromagnets that can be made to move vertically up and down the "lamp." We propose three separate magnets situated around the central cylinder in equal increments, each in its own separate, and smaller cylinder.
These can be made to pulsate, which we expect can be used to either split the liquid apart should it turn into a single ball (turning all 3 on simultaneously and briefly) or induce circular motion of the ferrofluid.

The plan is to allow the user to specify the speed at which the main electromagnets (ones on top and bottom) move the liquid up and down, as well as the movement and on/off operation of the three vertical magnets (interestingly, the user could have the 3 magnets do completely different things... the result of which we are yet unable to visualize).

To achieve the vertical movement of the three outer magnets, motors will be incorporated into our design.

As an aside, we realize that the three outer magnets can be used to achieve upwards and downwards movement. In this way, our design is somewhat redundant. However, we also want to allow the user the option to simply have the fluid drift upwards and downwards, without any horizontal interference.

Mobile Hive Checker

Rawda Abdeltawab, Fiona Cashin, Olivia Guido

Featured Project

# Team Members:

- Fiona Cashin (fcashin2)

- Olivia Guido (ojguido2)

- Rawda Abdeltawab (rawdaka2)

# Problem

Beekeepers must routinely monitor hive conditions to maintain healthy colonies. However, manually opening a hive significantly stresses the bees and disrupts their environment, and frequent disturbances can negatively affect bee behavior and productivity. On the other hand, insufficient monitoring can lead to swarming or freezing, resulting in the loss of an entire colony. Each lost colony can cost a beekeeper between $100 and $200. This highlights the need for a non-invasive solution for assessing the health of multiple hives, while minimizing stress on the bees. Although monitoring systems are available, they typically cost around $100 per hive, and many of the leading companies in this space are headquartered in Europe.

# Solution

The proposed solution is a portable device that enables beekeepers to monitor a colony’s health without opening the hive. A small sensor probe is inserted into the hive entrance to collect internal environmental data while the main unit remains outside. The device displays active sensor readings on an integrated screen and indicates whether hive conditions fall within acceptable ranges, such as temperatures between 70 and 97 degrees Fahrenheit. This approach minimizes hive disturbance while still providing essential health data including temperature, humidity, and carbon dioxide levels.

# Solution Components

## Subsystem 1, Temperature and Humidity Monitoring

This subsystem measures the internal temperature and humidity of the beehive.

Maintaining proper temperature is critical for hive health, as bee eggs will not develop and adult bees may die if the internal temperature falls outside the range between 70 and 97 degrees Fahrenheit. Humidity levels must remain between 50 percent and 60 percent to allow nectar to dry into honey. Excess humidity can promote pest reproduction, while insufficient humidity can cause bee eggs to dehydrate.

The device will use a temperature and humidity sensor connected via a long cable, allowing the sensor to be inserted into the hive while the user holds the device externally. The sensor will interface with a microcontroller unit (MCU), which will process the data and display the readings on an LCD screen. The MCU will evaluate whether the temperature and humidity values fall within the acceptable ranges. If the readings are normal, the display will show “PASSED.” If any reading is outside the normal range, the display will show “FAILED.”

Components:

- Digital Temperature Humidity Sensor : HiLetgo DHT21

- Microcontroller Unit (MCU) : ESP32-C3-WROOM-02

- Liquid Crystal Display (LCD) : B0DN9NMBFW (GODIYMODULES) or B0BWTFN9WF (Hosyond)

## Subsystem 2, Carbon Dioxide Monitoring

This subsystem measures the carbon dioxide concentration within the hive.

In a beehive, CO2 levels can be tolerated to a level of 8 percent, with higher levels indicating overcrowding and poor ventilation. The device will include a CO2 sensor connected via cable to the same MCU. The MCU will record the CO2 levels and display the results on the LED. As with the temperature and humidity subsystem, the MCU will determine whether the CO2 level is within the acceptable range and display “PASSED” or “FAILED” accordingly.

Components:

- CO2 Sensor : HiLetgo MHZ19

- Microcontroller Unit (MCU) : ESP32-C3-WROOM-02

- Liquid Crystal Display (LCD) : B0DN9NMBFW (GODIYMODULES) or B0BWTFN9WF (Hosyond)

## Subsystem 3, Microcontroller and Logic

The microcontroller coordinates all the subsystems and implements a Finite State Machine (FSM).

The MCU runs embedded C firmware that defines an FSM with at least four states, including “Start”, “Reset”, “Testing”, and “Done”. During the “Testing” state, sensor data is acquired via the appropriate communication protocols. Once testing is complete, the collected data is displayed on the LCD, allowing the user to assess the overall health of the hive. The MCU compares the data with the specified range to determine if the data is within range. This will prompt either a passed or failed responses to be displayed on the device

Components:

-Microcontroller Unit (MCU) : ESP32- option could be Espressif ESP32-C3-WROOM-02 which has RISC-V 32 bit CPU, antenna built-in, bluetooth, WIFI

-Programming Interface: use USB to upload code. USB can either charge battery/upload code, Arduino IDE platform

-Rest Button: PTS645SL43-2 LFS, resting the data on LCD to test another hive

-Power ON Button: PTS645SL43-2 LFS

-Liquid Crystal Display (LCD): B0DN9NMBFW (GODIYMODULES) or B0BWTFN9WF (Hosyond)

# Criterion For Success

- The humidity sensor accurately measures humidity.

- The temperature sensor accurately measures temperature.

- The display correctly shows the measured temperature.

- The display correctly shows the measured humidity.

- The display turns on when the ON button is pressed.

- A Start screen is shown when the ON button is pressed.

- A Testing screen is shown after the Start screen.

- A Done screen is displayed when the ON button is pressed the second time.

- A Reset Screen is displayed when the reset button is pressed.

- The display correctly shows “PASSED” and “FAILED.”

- The display shows “PASSED” when all sensor readings are within normal ranges.

- The display shows “FAILED” when at least one sensor reading is outside the normal range.

- Final product tested on multiple hives.

Project Videos